Installation
Instructions
- Download the software.
- Unzip
the contents of the zip file into a temporary directory.
For Mark 1 Units:
- Connect
a serial cable between the debug port on the
150 and a suitable port on the PC.
- While holding down
the program enable button on
the mother board; reset the unit. After 2 seconds release the program
enable button.
- If you are not
using COM1 port you will need to edit the batch file 'prog.bat'
and change the line @Flashldr.exe
init com1 baud=57.6k to reflect the port you wish to use.
- On the PC, using
the DOS prompt function select the directory where the firmware
was unzipped.
- Type 'prog.bat' and Return.
The screen should report that the processor has been initialise.
If it fails to do so exit the programme by typing 'exit' Return
and run prog.bat again.
- Type rom and Return.
The screen should report the progress of the upload.
- When the upload
has finished, type 'sh' Return and then 'exit' Return.
Reset the unit, the PC should
show the 150 booting.
- Disconnect
the cable and reboot the 150 again.
For mark 2 units:
- Remove the top of the unit
- Locate and remove the CF card, it's plugged into
the processor card which is on the main board, just pull it out
and slide it past the support pillar.
- Backup
the original HSG150B.EXE file on the CF card just in case this file
got corrupted.
- Copy
the new HSG150B.EXE file onto the CF card.
- Replace
the CF card in the processor, be careful to align the card in the
socket correctly.
- Boot
the system and check it function correctly.
Version
History
Version 2.h.3:
- Corrected problem with
resend messages when unit is slaved to a master.
- Improved fire routines
when in slave mode so that the fire deviation is reduced.
- Modified the way that
data is transmitted to the master so that repeat messages are reduced.
- Add facility to transmit
external data over the radio system. This is a transparent conduit
that does not affect the operation of the system. The terminator
character must be known and entered into the system so that the
end each message can be recognised
Version
2.g.1:
- Corrected problem with
Search Delay. This version requires MiniPulse 2.a.5.
Version 2.f.1:
- Added FM transducer
(depth/pressure) capture.
- Improved
sign on of MiniPulse to local slave.
Version 2.e.1:
- Modified to allow Depth
alarm.
- Corrected
gun sensor display.
Version 2.d.1:
- Depth and pressure transducers are now objected so that any channel
can be a depth or pressure. Also, each channel has its own offset
value.
Version 2.b.1:
- Enhanced telemetry collision
avoidance routine.
- Changed transmit routine
so that all slave units other than active slave are quiet during
fire period.
Version 2,a.1:
- First working release of HP150.
- Enhanced telemetry flow control and inter-unit messaging.
- Added pseudo sensor and depth information for test purposes.
Version 1.a.1:
- First public release of HP150.
Known Bugs
Contact
Information
If you have any questions, comments, suggestions, or bug reports
for the HP150, contact stuart@hydrasystems.co.uk. When submitting
bug reports, please include at the very least the following information:
- Operating system and version you're using (i.e. Windows 95 build
1111)
- Version of MiniPulse you're using (i.e. 1.h.1)
- What error message(s) (if any) you get
- Any other information you think would help in tracking the error
down
|